12
Installation
3.2 Installation of PHC10-2 controller
Both versions of the PHC10-2 controller can be used in a 19” rack system or as a stand-alone unit.
WARNING: Ensure the controller is disconnected from the mains supply during installation.
WARNING: Take care not to exceed the operation ambient of 50 °C around the unit. Do not install
near sources of heat. Forced cooling may be required in final installation.
The dimensions of the controller are as follows:
Width: 290 mm (11.42 in)
Height: 88 mm (3.46 in)
Depth: 220 mm (8.66 in)
Weight: 2.8 kg (98.7 oz)
NOTE: Use the mounting screws supplied with this equipment. DO NOT replace with longer screws as
damage could occur.
3.2.1 Stand-alone installation
Four self-adhesive rubber feet are supplied with the unit for stand-alone use.
3.2.2 Mounting alone in a 19” rack
Figure 12 shows the PHC10-2 ready for mounting to a 19” rack.
Figure 12 - Mounting PHC10-2 in a 19” rack
!
!